A rule of thumb, not a load calculation
This calculator multiplies floor area by a "BTU per square foot" factor that rises in colder climates. It's a quick sanity check, not a proper sizing method. The heat a house needs depends on its insulation, windows, air leaks, ceiling height and local design temperature far more than its floor area. The right way to size a furnace is an ACCA Manual J load calculation, which a good HVAC contractor should do before quoting.
How the estimate works
Furnace input rating = heat output ÷ (AFUE ÷ 100)
Furnaces are labeled with an input rating (the fuel burned per hour) and an output rating (the heat delivered). AFUE links them over a year. The Department of Energy explains that an AFUE of 90% means 90% of the energy in the fuel becomes heat for the home; the rest escapes up the chimney and elsewhere.
| Climate zone (IECC) | Rule-of-thumb factor used here |
|---|---|
| 1–2 (hot) | 30 BTU per sq ft |
| 3 (warm) | 35 |
| 4 (mixed) | 40 |
| 5 (cool) | 45 |
| 6 (cold) | 50 |
| 7–8 (very cold) | 60 |
These factors are typical rule-of-thumb figures, not a published standard. A tight, well-insulated house may need far less; an old, drafty one more. Change the factor if you know better.
Worked example
A 2,000 sq ft house in zone 4 at 40 BTU per sq ft needs about 2,000 × 40 = 80,000 BTU/h of heat. A 95% AFUE furnace needs an input rating of 80,000 ÷ 0.95 = 84,211 BTU/h; an 80% AFUE furnace needs 80,000 ÷ 0.80 = 100,000 BTU/h.
Why not just go bigger?
An oversized furnace heats the house in short bursts, cycling on and off more often. That wastes fuel, wears parts and leaves rooms less even. DOE notes that many older systems are oversized, and recommends improving insulation and air sealing before choosing a new furnace and having a heating contractor size it.