Insulation calculator

Enter the area, the R-value you have and the one you want, and the coverage on the bag, to see how thick the new layer is and how many bags to buy.

Private: calculated on your device. Nothing you type is sent anywhere.

Next: Insulating before replacing the furnace? Get a rough size with the furnace size calculator.

How it's calculated

R-value measures how well insulation resists heat flow; higher is better. Layers add up, so the R-value you need to add is the target minus what's already there.

R to add = target R − existing R
Thickness (in) = R to add ÷ R-value per inch
Bags or packages = area ÷ coverage per bag, rounded up

Coverage depends on the product and the R-value, so read it off the label. Blown-in bags have a chart showing the square feet each bag covers at R-30, R-38, R-49 and so on. Batts and rolls give the square feet per package for that R-value.

Worked example

A 1,000 sq ft attic with no insulation, aiming for R-49 with cellulose at R-3.6 to R-3.8 per inch: 49 ÷ 3.8 = 12.9 to 49 ÷ 3.6 = 13.6, so 12.9 to 13.6 inches. If the bag says it covers 40 sq ft at R-49: 1,000 ÷ 40 = 25 bags. If there's already R-19, add R-30: 7.9 to 8.3 inches.

DOE recommended R-values by climate zone

The U.S. Department of Energy recommends these levels for existing wood-framed homes, based on the 2021 International Energy Conservation Code. CI means continuous insulation, a layer of rigid board on the outside of the wall under the siding.

ZoneUninsulated atticAttic with 3–4 in alreadyFloorUninsulated wood-frame wall
1R30–R49R19–R38R13R13, or R0 + R10 CI
2R49–R60R38–R49R13R13, or R0 + R10 CI
3R49–R60R38–R49R19R20, or R13 + R5 CI, or R0 + R15 CI
4 (except Marine)R60R49R19R20 + R5 CI, or R13 + R10 CI, or R0 + R15 CI
4 Marine and 5R60R49R30R20 + R5 CI, or R13 + R10 CI, or R0 + R15 CI
6R60R49R30R20 + R5 CI, or R13 + R10 CI, or R0 + R20 CI
7 and 8R60R49R38R20 + R5 CI, or R13 + R10 CI, or R0 + R20 CI

Zone 1 is the hottest and zone 8 the coldest. The IECC climate zone map shows which zone your county is in.

R-value per inch

From the Department of Energy's guide to insulation materials. Fiberglass batts aren't given per inch by DOE, so their range is worked out from DOE's R-13 to R-15 batts for a 3.5 in (2×4) wall.

MaterialR-value per inch
Loose-fill celluloseR-3.6 to R-3.8
Fiberglass battsabout R-3.7 to R-4.3 (R-13 to R-15 in a 3.5 in wall)
CottonR-3.4
Sheep's woolabout R-3.5
Open-cell spray polyurethaneabout R-3.6
Closed-cell spray polyurethaneR-5.5 to R-6.5
Polystyrene foam boardR-3.8 to R-5.0
Polyisocyanurate boardR-5.6 to R-8.0
Phenolic foamR-4.8
Cementitious foamabout R-3.9
Vermiculite or perliteup to R-2.4

Limitations

  • Compressed insulation loses R-value. Don't squash batts into a cavity thinner than they're made for.
  • Loose-fill settles, so the label's "minimum settled thickness" is what counts. Use the bag's chart, not just R-value per inch.
  • Air sealing matters. Seal gaps around pipes, wires, lights and the attic hatch first; insulation doesn't stop air leaks.
  • Framing lowers the whole-wall R-value, because wood studs conduct heat more than insulation does.

Sources

How we checked this

Before every update, this calculator is run in a real browser with these known answers, and it must match all of them:

  • 1,000 sq ft attic, R-0 to R-49 with cellulose (R-3.6 to 3.8 per inch): 12.9 to 13.6 in ✓
  • Same: 40 sq ft per bag means 25 bags ✓
  • Topping up R-19 to R-49 adds R-30: 7.9 to 8.3 in of cellulose ✓
  • Edge: R-49 already at an R-38 target needs nothing more ✓

Last checked October 26, 2026. Spotted something wrong? The math is done in your browser with the formula shown on this page, so you can check any result by hand.

Add this calculator to your website (free)

Paste this code into any web page. The calculator works on your page, resizes itself, has no ads and no tracking cookies, and nothing your visitors type is sent anywhere. More about embedding.

Questions people ask

How many inches of insulation is R-49?

About 12.9 to 13.6 inches of cellulose (R-3.6 to R-3.8 per inch). Blown fiberglass usually needs more depth; check the bag's chart for the settled thickness.

What R-value should my attic be?

DOE recommends R-60 for an uninsulated attic in zones 4 to 8, R-49 to R-60 in zones 2 and 3, and R-30 to R-49 in zone 1.

How many bags of blown-in insulation do I need?

Divide the attic area by the bag's coverage at your target R-value. For example, 1,000 sq ft at 40 sq ft per bag is 25 bags.

Can I put new insulation over old insulation?

Usually yes, if the old insulation is dry and not moldy. Its R-value adds to the new layer's. Don't put a vapor-retarder-faced batt on top of existing insulation.

Does R-value add up when you layer insulation?

Yes. DOE says to add the R-values of the individual layers. R-19 plus R-30 is R-49.